ZONG Xinran,CHEN Haijun*   

  1. National Key Laboratory of Science and Technology on Vacuum Devices,The 12th Research Institute of China Electronics Technology Group Corporation,Beijing 100015,China
  • Online:2025-03-15 Published:2025-03-27

摘要: 环境中的杂散磁场以及电路部分产生的磁场会导致相干布居囚禁(Coherent Population Trapping,CPT)原子钟跃迁谱线的频移,从而影响其长期频率稳定度。为减小传统电加热温控设备引入的干扰磁场,研究采用了一种z型双层加热结构。通过有限元分析软件进行仿真,对比传统与新型加热片在原子气室中心产生的轴向磁场分布。结果显示,双层z型加热结构的干扰磁场强度约降低至传统加热片的0.05%,磁场均匀度提高了1 700倍以上。进一步调节双层加热片的各层电流,干扰磁场可减小到不足15 nT,且温度调节引起的磁场波动范围仅为0.33 nT。磁屏蔽环境下的测试结果与仿真相符,显著提升了CPT原子钟的长期频率稳定度。

关键词: 原子钟, 相干布居囚禁, 磁场强度, 电加热, 频移, 频率稳定度

Abstract: Environmental stray magnetic fields and those generated by circuit components can cause frequency shifts in the transition spectral lines of CPT(Coherent Population Trapping) atomic clocks,thus affect their long-term frequency stability.To reduce the interference magnetic fields introduced by traditional electric heating temperature control devices,a dual-layer heating z-type structure was adopted.Simulation was conducted using finite element analysis software to compare the distribution of axial magnetic fields generated by traditional and novel heating elements in an atomic cell.Results indicated that the interference magnetic field intensity of the dual-layer z-type heating structure could be reduced to 0.05% of that of traditional heating elements,and magnetic field uniformity improved by over 1 700 times.Further adjustments of the currents in each layer of the dual-layer heating elements could reduce the interference magnetic field to less than 15 nT,and the magnetic field fluctuation range due to temperature adjustments was just 0.33 nT.Tests in a magnetically shielded environment showed that the actual results were consistent with the simulations,significantly enhancing the long-term frequency stability of the CPT atomic clock.

Key words: Atomic clock, Coherent Population Trapping(CPT), Magnetic field intensity, Electric heating, Frequency shift, Frequency stability