JOURNAL OF ASTRONAUTIC METROLOGY AND MEASUREMENT ›› 2015, Vol. 35 ›› Issue (2): 43-48.doi: 10.12060/j.issn.1000-7202.2015.02.11

Previous Articles     Next Articles

Investigation on Technology of Doublepulse Transient Speckle Vibration Measurement

WEN Ju-ying1;ZHANG Da-zhi 2;CHEN Lin1;SHI Wei-ke3   

  1. 1、China Academy of Launch Vehicle Technology Research and Develop Center, Beijing 100076;
    2、Changcheng Institute of Metrology & Measurement, Beijing 100095;
    3、96626 Unit of PLA, Zhejiang 322100
  • Online:2015-04-15 Published:2015-04-15

Abstract: Aiming at the impact of digital speckle pattern interferometry on the transient vibration measurements, the technology on double digital speckle pattern interferometry was conducted. Uniform distribution of laser beam energy by space filter is achieved, and double-pulse laser and high-speed camera work synchronously by controlling time accurately. The transient speckle interference pattern is acquired with the proposed method. The research seeks to investigate and provides transient vibration measurements with double-pulse interval from 2μs to 800μs.

Key words: Pulse, Transient response, Measurement, Vibration