JOURNAL OF ASTRONAUTIC METROLOGY AND MEASUREMENT ›› 2012, Vol. 32 ›› Issue (2): 22-26.doi: 10.12060/j.issn.1000-7202.2012.02.07

Previous Articles     Next Articles

Analysis and Calculation of Influencing Factors on Slug-Type Heat Flux Sensor

ZHANG Xiao-fei1;WANG Wen-ge1   

  1. 1、Beijing Aerospace Institute for Metrology and Measurement Technology,Beijing 100076
  • Online:2012-04-15 Published:2012-04-15

Abstract: The structure and measurement principle of slugtype heat flux sensor are introduced. For a series of factors affecting the measurement results, such as the shape and size of  the sensitive component of the sensor, the thermal conductivity and thermal capacitance of the heat insulation layer and the surface emissivity of the two materials Etc., the heat transfer simulation to various models is conducted by Fluent software and the affections of different factors to the measurement results are analyzed. It can provide a reference and guidance for the development of the heat flux sensors.

Key words: Heat flux sensor, Software, Numerical simulation